{"id":8149,"date":"2026-11-10T01:11:36","date_gmt":"2026-11-10T01:11:36","guid":{"rendered":"https:\/\/www.tengyuemetering.com\/?p=8149"},"modified":"2026-11-10T02:32:26","modified_gmt":"2026-11-10T02:32:26","slug":"minimum-night-flow-water-leakage","status":"publish","type":"post","link":"https:\/\/www.tengyuemetering.com\/es\/minimum-night-flow-water-leakage\/","title":{"rendered":"What Is Minimum Night Flow (MNF)? Utility Guide"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8149\" class=\"elementor elementor-8149\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b87582 e-flex e-con-boxed e-con e-parent\" data-id=\"5b87582\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-89951f0 elementor-widget elementor-widget-text-editor\" data-id=\"89951f0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div data-page-id=\"BHCFddmhhottbSxOOLAcCHEPn3d\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\"><p class=\"ds-markdown-paragraph\"><span class=\"\">Minimum night flow (MNF) is the lowest recorded flow entering a defined water distribution area during a selected nighttime period. Water consumption changes throughout the day. In most distribution networks, demand decreases during late-night hours when fewer people and businesses are using water. For water utilities, this quieter period provides an important opportunity to investigate potential leakage.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">MNF is one of the commonly used indicators in water loss management. When analyzed together with other operational information, it can help utilities identify areas that may require further investigation. It is not a direct measurement of leakage, and it should not be treated as a standalone leak detector. Its value comes from trend comparison, operational context, and a structured follow-up process.<\/span><\/p><h2><span class=\"\">What Does Minimum Night Flow Mean in a DMA?<\/span><\/h2><p class=\"ds-markdown-paragraph\"><span class=\"\">In a District Metered Area (DMA), utilities monitor the flow entering the zone and analyze how it changes over time. During the night, legitimate consumption usually decreases. If the measured inflow remains unexpectedly high, background leakage may be one possible explanation.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">However, MNF is not a direct measurement of leakage. Nighttime consumption, industrial activities, storage tanks, pressure conditions, and other operational factors must also be considered. IWA water loss methodology and AWWA M36 provide widely used frameworks for interpreting flow and leakage indicators; both emphasize that nighttime flow should be assessed with supporting data rather than in isolation.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">A practical definition should specify the nighttime window, the averaging method, and the baseline period. For example, a utility might define MNF as the average flow between 02:00 and 04:00, compared with a 28-day rolling baseline. These are illustrative choices, not universal rules. Local demand patterns, network size, and data completeness should determine the final method.<\/span><\/p><h2><span class=\"\">Why Minimum Night Flow Matters for Water Utilities<\/span><\/h2><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Identifying potential background leakage.<\/span><\/strong><span class=\"\"> Small leaks may continue for long periods without producing visible signs on the surface. By comparing nighttime flow with historical patterns and expected legitimate consumption, utilities can identify zones that deserve closer attention.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Comparing performance between DMAs.<\/span><\/strong><span class=\"\"> A water network divided into DMAs can be monitored zone by zone. This allows utility teams to compare nighttime flow trends across different areas, identify unusual changes, and prioritize field investigations.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Evaluating the impact of repair work.<\/span><\/strong><span class=\"\"> MNF trends can also help utilities review whether a repair or leakage-control activity has changed the flow pattern. Comparisons should use consistent monitoring periods and account for changes in demand and operating conditions.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">MNF is most useful when it supports prioritization, not when it is used to declare a leak. A sustained change in night flow tells a utility where to look next; it does not tell the utility exactly what is wrong.<\/span><\/p><h2><span class=\"\">How Does MNF Analysis Work?<\/span><\/h2><p class=\"ds-markdown-paragraph\"><span class=\"\">A practical MNF investigation generally involves five steps.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Step 1: Define the DMA.<\/span><\/strong><span class=\"\"> Establish a clearly defined monitoring area with known inlet flow measurement points. Boundary valves should be documented and their status confirmed.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Step 2: Collect flow data.<\/span><\/strong><span class=\"\"> Record flow data at suitable intervals and maintain consistent monitoring conditions. For trend review, 15-minute interval data is often useful. Meter accuracy and low-flow resolution should be checked against the expected nighttime flow range.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Step 3: Identify the nighttime flow pattern.<\/span><\/strong><span class=\"\"> Review the flow curve to identify the minimum nighttime period and compare it with historical baselines. A single unusual night is rarely enough; a sustained pattern over several nights is more informative.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Step 4: Consider legitimate night consumption.<\/span><\/strong><span class=\"\"> Account for residential use, commercial operations, industrial demand, and other authorized consumption. Hospitals, night-shift businesses, and storage tank filling can all keep nighttime flow elevated.<\/span><\/p><p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Step 5: Investigate unusual results.<\/span><\/strong><span class=\"\"> If a zone shows an unexpected increase, use additional information such as pressure data, GIS network records, and field inspections to narrow down the possible source. MNF narrows the question; field verification answers it.<\/span><\/p><div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"><div class=\"ds-scroll-area__gutters\"><div class=\"ds-scroll-area__horizontal-gutter\">\u00a0<\/div><div class=\"ds-scroll-area__vertical-gutter\">\u00a0<\/div><\/div><table><thead><tr><th><span class=\"\">Nighttime signal<\/span><\/th><th><span class=\"\">Possible interpretation<\/span><\/th><th><span class=\"\">Useful next check<\/span><\/th><\/tr><\/thead><tbody><tr><td><span class=\"\">Single high reading<\/span><\/td><td><span class=\"\">Temporary event, measurement issue, or short-term use<\/span><\/td><td><span class=\"\">Repeat measurement and check alarms<\/span><\/td><\/tr><tr><td><span class=\"\">Sustained rise over several nights<\/span><\/td><td><span class=\"\">Changed nighttime use, pressure change, or background leakage<\/span><\/td><td><span class=\"\">Review pressure, authorized use, and DMA inflow<\/span><\/td><\/tr><tr><td><span class=\"\">Rise with stable pressure<\/span><\/td><td><span class=\"\">Possible change in consumption or leakage<\/span><\/td><td><span class=\"\">Check night users and field conditions<\/span><\/td><\/tr><tr><td><span class=\"\">Rise with higher pressure<\/span><\/td><td><span class=\"\">Pressure-driven flow increase possible<\/span><\/td><td><span class=\"\">Review pressure management and baseline<\/span><\/td><\/tr><tr><td><span class=\"\">Gradual seasonal drift<\/span><\/td><td><span class=\"\">Demand or temperature effect possible<\/span><\/td><td><span class=\"\">Compare with seasonal baseline<\/span><\/td><\/tr><\/tbody><\/table><\/div><p class=\"ds-markdown-paragraph\"><span class=\"\">The table is a general guide, not a diagnostic rule. Interpretation depends on the DMA&#8217;s specific operating context.<\/span><\/p><h2><span class=\"\">Why DMA Management and Pressure Data Matter<\/span><\/h2><p class=\"ds-markdown-paragraph\"><span class=\"\">MNF analysis is more useful when the monitored area has clear boundaries and reliable inlet measurement. Without well-defined zones, it can be difficult to determine where water enters, where consumption occurs, and which area is responsible for an unusual flow pattern.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">A DMA management system can combine inlet flow measurement, pressure monitoring at selected points, water balance analysis, nighttime flow trend analysis, and GIS visualization of network assets. Pressure data is particularly important because higher nighttime pressure can increase background leakage and change the MNF baseline. Flow and pressure should be reviewed together, not separately.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">ISO 4064 is relevant to the accuracy of the inlet meter; a meter that cannot resolve low nighttime flow may distort MNF analysis. ISO 55000 asset management principles support risk-based decisions about which DMAs to investigate first and how to prioritize repairs.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\"><a href=\"https:\/\/www.tengyuemetering.com\/es\/ty-leakage-monitoring-system-dma-real-time-leak-detection-tengyue\/\">TY Leakage Monitoring<\/a> includes DMA management, water balance reconciliation, MNF trend analytics, GIS asset visualization, and pressure-leakage correlation to support structured leakage investigation. The exact functions depend on the selected configuration.<\/span><\/p><h2><span class=\"\">Can Minimum Night Flow Confirm a Leak?<\/span><\/h2><p class=\"ds-markdown-paragraph\"><span class=\"\">A high MNF value does not automatically confirm a leak. It indicates that the area may need further analysis. Utilities should consider legitimate nighttime consumption, pressure conditions, meter performance, and operational changes before deciding where to send repair teams.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">MNF helps identify a potential water-loss problem within a monitored area, but it does not automatically identify the exact pipe or leak point. More detailed localization may require pressure-flow correlation, nested DMA analysis, GIS network information, and field verification.<\/span><\/p><h3><span class=\"\">Illustrative Scenario: A Sustained Nighttime Flow Increase<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">Consider a desensitized example. A DMA with about 1,350 connections has a 28-day nighttime baseline of 3.4 m\u00b3\/h between 02:00 and 04:00. Over six consecutive nights, average flow rises to 4.8 m\u00b3\/h\u2014about a 41% increase\u2014while pressure remains broadly stable and known nighttime users report no change.<\/span><\/p><p class=\"ds-markdown-paragraph\"><span class=\"\">The utility reviews DMA inflow and pressure logs, confirms the pattern is sustained, and uses GIS asset information and step testing to narrow the investigation area. Field verification then determines whether the cause is leakage, a valve issue, or an unrecorded night user. This example is illustrative and should not be read as a universal threshold.<\/span><\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4a197e elementor-widget elementor-widget-text-editor\" data-id=\"c4a197e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><span class=\"\">Frequently Asked Questions About Minimum Night Flow<\/span><\/h2><h3><span class=\"\">What is minimum night flow (MNF)?<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">MNF is the lowest recorded flow entering a defined area, such as a DMA, during a selected nighttime period. It is used as an indicator for investigating potential background leakage when legitimate nighttime consumption is low.<\/span><\/p><h3><span class=\"\">Does a high minimum night flow always mean leakage?<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">No. Hospitals, industry, storage tanks, night-shift businesses, and other authorized uses can keep nighttime flow elevated. Pressure changes and metering issues can also affect readings. MNF should be interpreted with supporting operational data.<\/span><\/p><h3><span class=\"\">What is a good minimum night flow for a DMA?<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">There is no universal value. MNF depends on DMA size, customer mix, pressure, infrastructure condition, and legitimate nighttime use. Utilities should establish a local baseline and look for sustained deviations rather than compare raw values across different DMAs.<\/span><\/p><h3><span class=\"\">How long should MNF be monitored before drawing conclusions?<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">Many utilities review multiple nights and compare against a rolling baseline, such as 28 days, while also checking seasonal patterns. A single unusual night is rarely sufficient; a sustained pattern over several nights is more informative.<\/span><\/p><h3><span class=\"\">How does pressure affect minimum night flow?<\/span><\/h3><p class=\"ds-markdown-paragraph\"><span class=\"\">Higher nighttime pressure can increase background leakage and some consumption. Pressure management can change the MNF baseline, so flow and pressure should be reviewed together rather than in isolation.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e213e87 elementor-widget elementor-widget-text-editor\" data-id=\"e213e87\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.tengyuemetering.com\/es\/contact-us-tengyue-metering-smart-water-meters\/\">\u00a0If you are reviewing minimum night flow patterns or DMA performance, contact our engineers to discuss MNF analysis, pressure monitoring, and a structured leakage investigation workflow.<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-db0c45f e-flex e-con-boxed e-con e-parent\" data-id=\"db0c45f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Minimum night flow (MNF) is the lowest recorded flow entering a defined water distribution area during a selected nighttime period. Water consumption changes throughout the day. In most distribution networks, demand decreases during late-night hours when fewer people and businesses are using water. For water utilities, this quieter period provides an important opportunity to investigate [&hellip;]<\/p>","protected":false},"author":1,"featured_media":8150,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[23,1],"tags":[],"class_list":["post-8149","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-info-center"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering<\/title>\n<meta name=\"description\" content=\"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tengyuemetering.com\/es\/minimum-night-flow-water-leakage\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering\" \/>\n<meta property=\"og:description\" content=\"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tengyuemetering.com\/es\/minimum-night-flow-water-leakage\/\" \/>\n<meta property=\"og:site_name\" content=\"Tengyue Metering\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-10T01:11:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-10T02:32:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis-1024x1024.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"webadmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"webadmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/\"},\"author\":{\"name\":\"webadmin\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/7f94ecd152264ca95e361094db019c0d\"},\"headline\":\"What Is Minimum Night Flow (MNF)? Utility Guide\",\"datePublished\":\"2026-11-10T01:11:36+00:00\",\"dateModified\":\"2026-11-10T02:32:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/\"},\"wordCount\":1341,\"publisher\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png\",\"articleSection\":[\"Blog\",\"Info Center\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/\",\"url\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/\",\"name\":\"What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering\",\"isPartOf\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png\",\"datePublished\":\"2026-11-10T01:11:36+00:00\",\"dateModified\":\"2026-11-10T02:32:26+00:00\",\"description\":\"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage\",\"url\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png\",\"contentUrl\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png\",\"width\":1254,\"height\":1254,\"caption\":\"MNF analysis and DMA water balance workflow for leakage investigation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tengyuemetering.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Info Center\",\"item\":\"https:\/\/www.tengyuemetering.com\/category\/info-center\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Blog\",\"item\":\"https:\/\/www.tengyuemetering.com\/category\/info-center\/blog\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"What Is Minimum Night Flow (MNF)? Utility Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#website\",\"url\":\"https:\/\/www.tengyuemetering.com\/\",\"name\":\"Tengyue Metering\",\"description\":\"Smart Water Meter Manufacturer\",\"publisher\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tengyuemetering.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#organization\",\"name\":\"Tengyue Metering\",\"url\":\"https:\/\/www.tengyuemetering.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2024\/12\/87f194b8255907fc319b6cfa2ea9a24d.png\",\"contentUrl\":\"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2024\/12\/87f194b8255907fc319b6cfa2ea9a24d.png\",\"width\":789,\"height\":226,\"caption\":\"Tengyue Metering\"},\"image\":{\"@id\":\"https:\/\/www.tengyuemetering.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/7f94ecd152264ca95e361094db019c0d\",\"name\":\"webadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/670f32ddd0cc8154ae4f92bea95515c1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/670f32ddd0cc8154ae4f92bea95515c1?s=96&d=mm&r=g\",\"caption\":\"webadmin\"},\"sameAs\":[\"http:\/\/www.tengyuemetering.com\"],\"url\":\"https:\/\/www.tengyuemetering.com\/es\/author\/webadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering","description":"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tengyuemetering.com\/es\/minimum-night-flow-water-leakage\/","og_locale":"es_ES","og_type":"article","og_title":"What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering","og_description":"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.","og_url":"https:\/\/www.tengyuemetering.com\/es\/minimum-night-flow-water-leakage\/","og_site_name":"Tengyue Metering","article_published_time":"2026-11-10T01:11:36+00:00","article_modified_time":"2026-11-10T02:32:26+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis-1024x1024.png","type":"image\/png"}],"author":"webadmin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"webadmin","Est. reading time":"8 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#article","isPartOf":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/"},"author":{"name":"webadmin","@id":"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/7f94ecd152264ca95e361094db019c0d"},"headline":"What Is Minimum Night Flow (MNF)? Utility Guide","datePublished":"2026-11-10T01:11:36+00:00","dateModified":"2026-11-10T02:32:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/"},"wordCount":1341,"publisher":{"@id":"https:\/\/www.tengyuemetering.com\/#organization"},"image":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png","articleSection":["Blog","Info Center"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/","url":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/","name":"What Is Minimum Night Flow (MNF)? Utility Guide| Tengyue Metering","isPartOf":{"@id":"https:\/\/www.tengyuemetering.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage"},"image":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png","datePublished":"2026-11-10T01:11:36+00:00","dateModified":"2026-11-10T02:32:26+00:00","description":"Learn what minimum night flow means, how water utilities use MNF analysis, and why DMA monitoring helps investigate background leakage.","breadcrumb":{"@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#primaryimage","url":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png","contentUrl":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2026\/11\/MNF-analysis.png","width":1254,"height":1254,"caption":"MNF analysis and DMA water balance workflow for leakage investigation"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tengyuemetering.com\/minimum-night-flow-water-leakage\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tengyuemetering.com\/"},{"@type":"ListItem","position":2,"name":"Info Center","item":"https:\/\/www.tengyuemetering.com\/category\/info-center\/"},{"@type":"ListItem","position":3,"name":"Blog","item":"https:\/\/www.tengyuemetering.com\/category\/info-center\/blog\/"},{"@type":"ListItem","position":4,"name":"What Is Minimum Night Flow (MNF)? Utility Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.tengyuemetering.com\/#website","url":"https:\/\/www.tengyuemetering.com\/","name":"Tengyue Metering","description":"Smart Water Meter Manufacturer","publisher":{"@id":"https:\/\/www.tengyuemetering.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tengyuemetering.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.tengyuemetering.com\/#organization","name":"Tengyue Metering","url":"https:\/\/www.tengyuemetering.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.tengyuemetering.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2024\/12\/87f194b8255907fc319b6cfa2ea9a24d.png","contentUrl":"https:\/\/www.tengyuemetering.com\/wp-content\/uploads\/2024\/12\/87f194b8255907fc319b6cfa2ea9a24d.png","width":789,"height":226,"caption":"Tengyue Metering"},"image":{"@id":"https:\/\/www.tengyuemetering.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/7f94ecd152264ca95e361094db019c0d","name":"webadmin","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.tengyuemetering.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/670f32ddd0cc8154ae4f92bea95515c1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/670f32ddd0cc8154ae4f92bea95515c1?s=96&d=mm&r=g","caption":"webadmin"},"sameAs":["http:\/\/www.tengyuemetering.com"],"url":"https:\/\/www.tengyuemetering.com\/es\/author\/webadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/posts\/8149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/comments?post=8149"}],"version-history":[{"count":4,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/posts\/8149\/revisions"}],"predecessor-version":[{"id":8155,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/posts\/8149\/revisions\/8155"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/media\/8150"}],"wp:attachment":[{"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/media?parent=8149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/categories?post=8149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tengyuemetering.com\/es\/wp-json\/wp\/v2\/tags?post=8149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}